1 It is a one body trolley structure, easy handling at site.

2 You can do site test without complex wiring, because all test modes and switching voltage levels are automatically switched by weak control internal high-voltage switches.

3 It can quickly locate and point low resistance, high impedance fault leakage, flashover faults in power cable with a variety of 220V-220KV voltage level.

Characteristics

1 It integrates multi-gear DC high-voltage generator, multi-gear high-voltage capacitor, arc-stabling units and a variety of signal acquisition in one body, which facilitates fault location operation.

2 Switching between three gear test modes, two gear voltage levels is controlled by low-voltage weak electricity.

3 World's leading test method makes difficult fault detecting become very simple.

4 The requirement to operators’ level for technical equipment is low.

5 The DC voltage is up to 32kV.

6 Each stall of voltages, which is 16 / 32kV, can output up to 1536 J impact energy. It has longer ranging delay arc time and makes a loud voice on the fault point when locating.

7 It can do high impedance fault detection directly without burning.

6 Large wheels ensure a smooth, easy handling and site work.


Products

HZ-501A Cable fault location system

Advantages

Introduction

1 It is a one body trolley structure, easy handling at site.

2 You can do site test without complex wiring, because all test modes and switching voltage levels are automatically switched by weak control internal high-voltage switches.

3 It can quickly locate and point low resistance, high impedance fault leakage, flashover faults in power cable with a variety of 220V-220KV voltage level.

Characteristics

1 It integrates multi-gear DC high-voltage generator, multi-gear high-voltage capacitor, arc-stabling units and a variety of signal acquisition in one body, which facilitates fault location operation.

2 Switching between three gear test modes, two gear voltage levels is controlled by low-voltage weak electricity.

3 World's leading test method makes difficult fault detecting become very simple.

4 The requirement to operators’ level for technical equipment is low.

5 The DC voltage is up to 32kV.

6 Each stall of voltages, which is 16 / 32kV, can output up to 1536 J impact energy. It has longer ranging delay arc time and makes a loud voice on the fault point when locating.

7 It can do high impedance fault detection directly without burning.

6 Large wheels ensure a smooth, easy handling and site work.


Indicators

1 Test methods: Arc reflection method, current sampling, and DC output.

2 Types of sampling signals: Arc reflection method, current sampling, and low-voltage pulse.

3 DC voltage output:

  0 ~ 32kV Negative   Maximum output current: 76mA

0 ~ 16kV Negative   Maximum output current: 152mA

4 Impact capacitor:

0 ~ 32kV 3μF Maximum output energy: 1536 joules

0 ~ 16kV 12μF Maximum output energy: 1536 joules

5 Ball-gap discharge: Weak electricity control. Discharge cycle can be adjusted within 3-12 seconds. It has a specially designed silencer, which meets the requirement of silence when fault happened to the initial end cable.

6 Protection:

  Zero voltage position protection: To prevent misuse, and to protect the safety of personal and the test product;

  Press "off" button, and it will release the remaining charge automatically through safety instrument inside to ensure safety.

7 It is equipped with extension cable tray, which can be composed of automotive cable fault location system.


Contrast

Model

HZ-4000T1

HZ-4000T2

HZ-4000T3

Test mode

Arc reflection method, current sampling, DC output

Arc reflection method, DC arc reflection method, current sampling, voltage sampling (optional), DC output

Sampling signal type

Arc reflection method, current sampling, low voltage pulse

Arc reflection method, DC arc reflection method, current sampling, voltage sampling (optional), low voltage pulse

DC high voltage output

The maximum output current of 0 ~ 16KV negative polarity: 76mA

The maximum output current of 0 ~ 32KV negative polarity: 76mA

The maximum output current of 0 ~ 32KV negative polarity: 76mA

The maximum output current of 0 ~ 8KV negative polarity: 152mA

The maximum output current of 0 ~ 16KV negative polarity: 152mA

The maximum output current of 0 ~ 16KV negative polarity: 152mA

The maximum output current of 0 ~ 8KV negative polarity: 304mA

Impact capacitance

0 ~ 16KV 7.5 F maximum output energy of 1000 Joule

0 ~ 32KV 3 F maximum output energy of 1536 Joule

0 ~ 32KV 4 F maximum output energy of 2048 Joule

0 ~ 8KV 30 F maximum output energy of 1000 Joule

0 ~ 16KV 12 F maximum output energy of 1536 Joule

0 ~ 16KV 16 F maximum output energy of 2048 Joule

0 ~ 8KV 64 F maximum output energy of 2048 Joule

Gap discharge

Weak electric control, the discharge cycle is adjustable for 3-12 seconds, and the silencing device is specially set to meet the requirement of the cable failure at the beginning.

Characteristic

Three gear test mode switching and two shift voltage level switching are all controlled by low voltage weak power control

Five test switch、Three voltage switching through low voltage control

The DC DC voltage is up to 16KV

The DC voltage is up to 32KV


Accessories

Cable Fault Location System

High voltage cable 8 meters

Ground wire 8 meters

power lines  1 

Extension of high voltage cable disc

Extension power line cable disk optional

Extension of grounding wire cable disk