Primary Technical Specifications
1.The capacitance range of the test object 6pF--250μF
2.Measuring sensitivity and Max. current(see table 1)
No.Tuning capacitance rangeSensitivity (pC)
(Un-balance circuit)RMS Of max. current
(Un-balance circuit)(Balance circuit)
10~25~100pF0.0230mA0.25A
225~100~400pF0.0450mA0.5A
3100~400~1500pF0.06120mA1A
4400~1500~6000pF0.10.25A2A
51500~6000~25000pF0.20.5A4A
60.006~0.025~0.1μF0.31A8A
70.025~0.1~0.4μF0.52A15A
80.1~0.4~1.5μF14A30A
90.4~1.5~6.0μF1.58A60A
101.5~6.0~25μF2.515A120A
116.0~25~60μF525A200A
1225~60~250μF1050A300A
7RResistor0.52A15A
Table 1
3. Band width:
(1) On low frequency 3dB, fL: 10kHz, 20kHz, 40 KHz optional
(2) On high frequency 3dB, fH: 80kHz, 200kHz, 300 KHz optional
4、Gain adjusting:
6 grades of rough gain. Gain between 2 near grades is 20±1dB, fine adjusting range >20dB
5、Time window:
① Window width: Adjustable within 15º~150º
② Window position: Rotatable within 0º~170º
③ Two windows can be set on/off respectively or simultaneously
6、Partial Discharge Meter:
Digital meter with 3.5 bits LED digital display,;
Partial discharge magnitude deviation within 0-100: <±5%
7、Ellipse time base:
① Frequency: 60 Hz, 120 Hz, 180 Hz, 240 Hz, 300Hz
② Ellipse rotation: 30º per grade, total 150º
③ Display mode: ellipse——line——sine
8、Test high voltage meter:
Range: 100kV (extensible)
② Display: 3½ digital voltage meter,precision better than ±5%(for full graduation)
9、It has zero-mark, which is useful to distinguish the partial discharge.
10、Size :460*420*260(Width*Length*Height)mm。
11、Weight: About 16kG.