I. Feature
High-voltage insulation resistance tester, with 8 range: 500V, 1000V, 2500V, 5000V, 10000V, 15000V, 20000V, 25000V, 30000V,test up to 30TΩ, manual voltage regulation function.
● Strict accordance with the safety standards for design
● Insulation resistance range 30TΩ @ 30 kv
● Short circuit current can be adjusted, maximum 5mA (Can be ordered as high as 10mA, short circuit current products).
● Automatic display polarization index (PI), induced electric absorption test values than (DAR), and can test the leakage current and capacitance.
● Anti-jamming performance is superior, the interference current reaches 2 mA, still ensure accuracy of test instruments.
● 2 methods for power: use of lithium ion batteries, battery life can be up to 4 hours (10000V @ 100MΩ).
● Insulation resistance simulation column.
● Digital filtering functions, external influence deviation display value causing mitigation point using filter function.
● Perfect protection function, and the spare fuse prompt functions.
II. Specification Parameter
● Safety Standard
IEC 61010-1 CAT.IV 600V
IEC 61326 EMC specification: test, control and electrical equipment for testing
IEC60529 IP64 (Outer closed state)
● AC Power:220V±10%,50/60 HZ ,20 VA
● battery:16.8V Lithium ion rechargeable battery
● Battery Life:10000V@100M, 4 hour
● size(L x W x H):37cm x 27cm x 14cm
● weight:3.6kg
● Test voltage accuracy: the nominal value 100% to 110%
● Voltage measurement accuracy:5%+3V
● Current test range:10mA
● current measure precision:5%+0.2nA
● short-circuit current: 5mA
● Capacitance test range:20uF
● Capacitance testing accuracy:15%+0.03uF
● Insulation resistance testing range and accuracy (T:23±5ºC ,RH :45 – 75%)
range accuracy | 500V | 1000V | 2500V | 5000V | 10000V |
Unspecified | <1M | <1M | <1M | <1M | <1M |
5% | 1M -10G | 1M -20G | 1M -100G | 1M -100G | 1M -200G |
20% | 10G -100G | 20G-200G | 100G-1T | 100G-1T | 200G-2T |
Unspecified | > 100G | > 200G | > 1T | > 1T | > 2T |
range accuracy | 15000V | 20000V | 25000V | 30000V | |
Unspecified | <1M | <1M | <1M | <1M | |
5% | 1M -300G | 1M -400G | 100k-200G | 100k-200G | |
20% | 300G -3T | 400G-4T | 200G-2T | 200G-2T | |
Unspecified | > 3T | > 4T | > 2T | > 2T |