在线客服系统
Huazheng Electric Manufacturing (Baoding) Co., Ltd.

HOME >> NEWS

2026-09
What Does Class 0.05 Mean? How Important Is the Accuracy Class of an On-Site Electric Energy Calibrator?
VIEW MORE

When purchasing instruments, the price difference between Class 0.05 and Class 0.2 may cause hesitation. Those involved in electrical energy metering verification understand that the accuracy class is not merely a performance parameter but also a critical factor determining whether the verification

What Does Class 0.05 Mean? How Important Is the Accuracy Class of an On-Site Electric Energy Calibrator?
2026-09
How to Do Ultra-Low Frequency Withstand Voltage Test for Power Cables? HZDP Operation Process and Voltage Calculation Method
VIEW MORE

The voltage withstand test of cables cannot be directly stepped up after connecting the wires. Whether the preliminary confirmation is done solidly is directly related to the test results and equipment safety. Taking the HZDP ultra-low frequency high-voltage generator as an example, the following ap

How to Do Ultra-Low Frequency Withstand Voltage Test for Power Cables? HZDP Operation Process and Voltage Calculation Method
2026-08
What Is the Polarization Index PI? Why Is R600/R60 More Reliable Than Absorption Ratio?
VIEW MORE

On the basis of absorption ratio DAR, HZJY-30KV can also automatically measure and calculate polarization index PI. If DAR is a "fast rough judgment" of insulation state, PI is a more in-depth "fine diagnosis" - the two use different time scales and are applicable in different si

What Is the Polarization Index PI? Why Is R600/R60 More Reliable Than Absorption Ratio?
2026-08
Built in Three-Phase Inverter Power Supply: Without Voltage Regulator, It Can Also Measure Three-Phase Transformers on Site
VIEW MORE

In the past, when conducting transformer short-circuit impedance tests, a three-phase voltage regulator had to be prepared on site - it was bulky and heavy, and some remote substations could not be moved in at all. The design of HZ2611 with built-in three-phase inverter power supply has completely c

Built in Three-Phase Inverter Power Supply: Without Voltage Regulator, It Can Also Measure Three-Phase Transformers on Site
2026-08
Online Monitoring and Offline Discharge: How to Use the Two Major Functions of HZFD-200?
VIEW MORE

Some battery testers on the market can only perform "capacity verification discharge," requiring the battery to be disconnected from the system for testing, while others only support online monitoring without assessing actual capacity. The HZFD-200 integrates both functions into a single d

Online Monitoring and Offline Discharge: How to Use the Two Major Functions of HZFD-200?
+86-312-6775656 +86 13731210226 sales03@bdhuazheng.com